{"product_id":"grundfos-cre","title":"Grundfos CRE Vertical Multistage Pump with Integrated Drive","description":"\u003cp class=\"mt-4 border-l-2 border-marine pl-5 text-[17px] font-medium leading-snug text-navy\"\u003eVertical multistage pump with an MGE E-motor, so the speed control and the motor protection are inside the terminal box rather than in the panel.\u003c\/p\u003e\n\u003cp class=\"mt-4 text-[15px] leading-relaxed text-slate-600\"\u003eThe Grundfos CRE is the vertical multistage CR fitted with an E-motor: a frequency converter built into the motor terminal box. With the integrated pressure sensor it holds a constant pressure as demand moves, without an external drive or a motor-protective circuit breaker. Hydraulics and materials are the CR's.\u003c\/p\u003e\n\u003ch2 class=\"text-[24px] font-semibold tracking-tight\"\u003eKey features\u003c\/h2\u003e\n\u003cdiv class=\"text-[15px] font-semibold text-navy\"\u003e\u003cstrong\u003eThe drive is in the terminal box, not the panel\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"prose max-w-none prose-slate prose-p:text-slate-600 prose-headings:text-navy prose-headings:font-semibold prose-headings:tracking-tight prose-a:text-marine prose-a:no-underline hover:prose-a:underline prose-strong:font-medium prose-strong:text-navy prose-li:text-slate-600 prose-blockquote:border-l-2 prose-blockquote:border-marine prose-blockquote:pl-5 prose-blockquote:font-medium prose-blockquote:not-italic prose-blockquote:text-navy [\u0026amp;_blockquote_p]:text-navy [\u0026amp;_blockquote_p:first-of-type::before]:content-none [\u0026amp;_blockquote_p:last-of-type::after]:content-none prose-p:text-[15px] mt-1 [\u0026amp;_p]:text-[14px]\"\u003e\n\u003cp\u003eThe MGE motor carries its own frequency converter, so there is no separate inverter to mount, wire, cool or find space for in the starter panel.\u003c\/p\u003e\n\u003cdiv class=\"text-[15px] font-semibold text-navy\"\u003e\u003cstrong\u003eNo motor-protective circuit breaker\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"prose max-w-none prose-slate prose-p:text-slate-600 prose-headings:text-navy prose-headings:font-semibold prose-headings:tracking-tight prose-a:text-marine prose-a:no-underline hover:prose-a:underline prose-strong:font-medium prose-strong:text-navy prose-li:text-slate-600 prose-blockquote:border-l-2 prose-blockquote:border-marine prose-blockquote:pl-5 prose-blockquote:font-medium prose-blockquote:not-italic prose-blockquote:text-navy [\u0026amp;_blockquote_p]:text-navy [\u0026amp;_blockquote_p:first-of-type::before]:content-none [\u0026amp;_blockquote_p:last-of-type::after]:content-none prose-p:text-[15px] mt-1 [\u0026amp;_p]:text-[14px]\"\u003e\n\u003cp\u003eGrundfos states that E-pump installations need only normal short-circuit protection for the cable. The converter protects the motor and the electronics against overload.\u003c\/p\u003e\n\u003cdiv class=\"text-[15px] font-semibold text-navy\"\u003e\u003cstrong\u003eSame hydraulics and metal as the CR\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"prose max-w-none prose-slate prose-p:text-slate-600 prose-headings:text-navy prose-headings:font-semibold prose-headings:tracking-tight prose-a:text-marine prose-a:no-underline hover:prose-a:underline prose-strong:font-medium prose-strong:text-navy prose-li:text-slate-600 prose-blockquote:border-l-2 prose-blockquote:border-marine prose-blockquote:pl-5 prose-blockquote:font-medium prose-blockquote:not-italic prose-blockquote:text-navy [\u0026amp;_blockquote_p]:text-navy [\u0026amp;_blockquote_p:first-of-type::before]:content-none [\u0026amp;_blockquote_p:last-of-type::after]:content-none prose-p:text-[15px] mt-1 [\u0026amp;_p]:text-[14px]\"\u003e\n\u003cp\u003eCast iron pump head and base, EN 1.4301 (AISI 304) stainless wetted parts, cartridge shaft seal. Grundfos builds the CRE on the CR, so the curve and the materials are unchanged.\u003c\/p\u003e\n\u003cdiv class=\"text-[15px] font-semibold text-navy\"\u003e\u003cstrong\u003eConstant pressure out of the box\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"prose max-w-none prose-slate prose-p:text-slate-600 prose-headings:text-navy prose-headings:font-semibold prose-headings:tracking-tight prose-a:text-marine prose-a:no-underline hover:prose-a:underline prose-strong:font-medium prose-strong:text-navy prose-li:text-slate-600 prose-blockquote:border-l-2 prose-blockquote:border-marine prose-blockquote:pl-5 prose-blockquote:font-medium prose-blockquote:not-italic prose-blockquote:text-navy [\u0026amp;_blockquote_p]:text-navy [\u0026amp;_blockquote_p:first-of-type::before]:content-none [\u0026amp;_blockquote_p:last-of-type::after]:content-none prose-p:text-[15px] mt-1 [\u0026amp;_p]:text-[14px]\"\u003e\n\u003cp\u003eOrder the CRE with the integrated pressure sensor and constant pressure is the factory control mode. Set the pressure you want and the pump varies its speed to hold it.\u003c\/p\u003e\n\u003cdiv class=\"text-[15px] font-semibold text-navy\"\u003e\u003cstrong\u003eIE5 motor efficiency across the range\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"prose max-w-none prose-slate prose-p:text-slate-600 prose-headings:text-navy prose-headings:font-semibold prose-headings:tracking-tight prose-a:text-marine prose-a:no-underline hover:prose-a:underline prose-strong:font-medium prose-strong:text-navy prose-li:text-slate-600 prose-blockquote:border-l-2 prose-blockquote:border-marine prose-blockquote:pl-5 prose-blockquote:font-medium prose-blockquote:not-italic prose-blockquote:text-navy [\u0026amp;_blockquote_p]:text-navy [\u0026amp;_blockquote_p:first-of-type::before]:content-none [\u0026amp;_blockquote_p:last-of-type::after]:content-none prose-p:text-[15px] mt-1 [\u0026amp;_p]:text-[14px]\"\u003e\n\u003cp\u003eGrundfos rates the MGE motor at IE5 level from 0.37 to 26 kW, with insulation class F and IP55 enclosure as standard, IP66 on request.\u003c\/p\u003e\n\u003cdiv class=\"text-[15px] font-semibold text-navy\"\u003e\u003cstrong\u003eSet and read it from a phone\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"prose max-w-none prose-slate prose-p:text-slate-600 prose-headings:text-navy prose-headings:font-semibold prose-headings:tracking-tight prose-a:text-marine prose-a:no-underline hover:prose-a:underline prose-strong:font-medium prose-strong:text-navy prose-li:text-slate-600 prose-blockquote:border-l-2 prose-blockquote:border-marine prose-blockquote:pl-5 prose-blockquote:font-medium prose-blockquote:not-italic prose-blockquote:text-navy [\u0026amp;_blockquote_p]:text-navy [\u0026amp;_blockquote_p:first-of-type::before]:content-none [\u0026amp;_blockquote_p:last-of-type::after]:content-none prose-p:text-[15px] mt-1 [\u0026amp;_p]:text-[14px]\"\u003e\n\u003cp\u003eMGE motors from 3 to 26 kW carry a Bluetooth module for Grundfos GO, so setpoint and operating data come off the pump without opening the terminal box.\u003c\/p\u003e\n\u003csection\u003e\n\u003ch2 class=\"text-[24px] font-semibold tracking-tight\"\u003eAbout the Grundfos CRE\u003c\/h2\u003e\n\u003cdiv class=\"mt-3\"\u003e\n\u003cdiv class=\"prose max-w-none prose-slate prose-p:text-slate-600 prose-headings:text-navy prose-headings:font-semibold prose-headings:tracking-tight prose-a:text-marine prose-a:no-underline hover:prose-a:underline prose-strong:font-medium prose-strong:text-navy prose-li:text-slate-600 prose-blockquote:border-l-2 prose-blockquote:border-marine prose-blockquote:pl-5 prose-blockquote:font-medium prose-blockquote:not-italic prose-blockquote:text-navy [\u0026amp;_blockquote_p]:text-navy [\u0026amp;_blockquote_p:first-of-type::before]:content-none [\u0026amp;_blockquote_p:last-of-type::after]:content-none prose-p:text-[15px]\"\u003e\n\u003cp\u003eThe Grundfos CRE is a vertical multistage centrifugal pump with a variable-speed drive built into the motor. It is a clean-water pump: Grundfos lists it for industrial and municipal water supply, distribution from waterworks, pressure boosting in mains and in high-rise buildings, washing and cleaning, water treatment, boiler feed and condensate, cooling and air-conditioning, machine tools and irrigation. The pump head and base are cast iron and every other wetted part is EN 1.4301 stainless steel, which is the AISI 304 grade. Non-corrosive liquids only.\u003c\/p\u003e\n\u003cp\u003eSizes run CRE 1 to CRE 155, where the number is roughly the rated flow in m³\/h, and each size carries a range of stage counts. Ports are in line, at the same level, so the pump drops into a horizontal pipe run. That is the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/channelpumps.com\/products\/grundfos-cr\"\u003eCR\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003elayout and the CRE inherits it, along with the chamber stack, the staybolts and the cartridge shaft seal. It sits in our\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/channelpumps.com\/categories\/centrifugal-pumps\"\u003ecentrifugal pump\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003ecategory and comes from\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/channelpumps.com\/manufacturers\/grundfos\"\u003eGrundfos\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat the integrated converter actually buys you\u003c\/h2\u003e\n\u003cp\u003eGrundfos is blunt about the difference: \"The difference between the CR and CRE pump ranges is the motor.\" The hydraulics, the materials and the seal are the same. What changes is that the motor is an MGE, and the MGE has a frequency converter inside its terminal box.\u003c\/p\u003e\n\u003cdiv class=\"my-5 overflow-x-auto\"\u003e\n\u003ctable class=\"m-0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eCR\u003c\/th\u003e\n\u003cth\u003eCRE\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eNo built-in frequency converter\u003c\/td\u003e\n\u003ctd\u003eMGE motor, converter built into the terminal box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed\u003c\/td\u003e\n\u003ctd\u003eFixed\u003c\/td\u003e\n\u003ctd\u003eContinuously variable, so any duty point on the curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstant pressure\u003c\/td\u003e\n\u003ctd\u003eNeeds a sensor and a controller finding space in the panel\u003c\/td\u003e\n\u003ctd\u003eIntegrated pressure sensor option; constant pressure is the factory setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor protection\u003c\/td\u003e\n\u003ctd\u003eMotor-protective circuit breaker\u003c\/td\u003e\n\u003ctd\u003eIn the converter. Short-circuit protection for the cable only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydraulics, chamber stack, shaft seal\u003c\/td\u003e\n\u003ctd\u003eSame\u003c\/td\u003e\n\u003ctd\u003eSame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetted materials\u003c\/td\u003e\n\u003ctd\u003eCast iron head and base, EN 1.4301 stainless\u003c\/td\u003e\n\u003ctd\u003eSame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003eRead that as a list of things you no longer buy and no longer commission. The inverter, its enclosure, its cooling and the cable run between panel and pump all disappear into the motor. So does the motor-protective circuit breaker. The pump arrives tested and pre-configured, and the person commissioning it types in a pressure.\u003c\/p\u003e\n\u003ch2\u003eWhen a plain CR is the better buy\u003c\/h2\u003e\n\u003cp\u003eGrundfos names three reasons to select an E-pump: the consumption fluctuates, you want constant pressure, or you want to communicate with the pump. If none of those is true, a CRE is money spent on control you will not use. A transfer duty that runs flat out into a tank does not vary, and a fixed-speed CR with a starter is the cheaper pump with less to go wrong.\u003c\/p\u003e\n\u003cp\u003eThe other check is where the pump lives. Putting the drive on the motor puts the electronics in the plant room, at whatever temperature and altitude the plant room happens to be. Grundfos calls for an oversize motor above 50 °C ambient or above 1000 metres, which is the sort of derate that turns a straightforward selection into a bigger frame size. Tell us the ambient and the site altitude when you enquire.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch2 class=\"text-[24px] font-semibold tracking-tight\"\u003eHow the Grundfos CRE works\u003c\/h2\u003e\n\u003cdiv class=\"mt-3\"\u003e\n\u003cdiv class=\"prose max-w-none prose-slate prose-p:text-slate-600 prose-headings:text-navy prose-headings:font-semibold prose-headings:tracking-tight prose-a:text-marine prose-a:no-underline hover:prose-a:underline prose-strong:font-medium prose-strong:text-navy prose-li:text-slate-600 prose-blockquote:border-l-2 prose-blockquote:border-marine prose-blockquote:pl-5 prose-blockquote:font-medium prose-blockquote:not-italic prose-blockquote:text-navy [\u0026amp;_blockquote_p]:text-navy [\u0026amp;_blockquote_p:first-of-type::before]:content-none [\u0026amp;_blockquote_p:last-of-type::after]:content-none prose-p:text-[15px]\"\u003e\n\u003cp\u003eA stack of impellers, each in its own chamber, adds pressure to the same flow. That is how a tall, narrow pump reaches 262 m of head. The CRE is not self-priming, so the inlet has to be flooded.\u003c\/p\u003e\n\u003cp\u003eThe E-motor is what makes it a CRE. Grundfos builds the MGE as a totally enclosed, fan-cooled motor with a frequency converter in the terminal box and a PI controller behind it. On a pump ordered with the integrated pressure sensor, the sensor on the outlet feeds pressure back to the controller, the controller compares it with the setpoint and the converter trims motor speed until the two agree. Because that runs continuously, the pressure in the pipework stays put while the draw on it changes. Two control modes ship on the pump: constant pressure, which is the factory setting, and constant curve.\u003c\/p\u003e\n\u003cp\u003eOrder a CRE without the sensor and you get open-loop speed control, or a pump ready for a sensor you fit later. That variant covers flow, level, temperature, differential pressure and differential temperature control, and it is also the one to specify when a remote analogue signal sets the speed from a building management system.\u003c\/p\u003e\n\u003cp\u003eProtection is inside the converter rather than the panel. The MGE carries thermal protection against slow overload and blocking, and Grundfos states that E-pump installations do not require a motor-protective circuit breaker, only normal short-circuit protection for the cable. Motors from 3 to 26 kW include a Bluetooth module that talks to Grundfos GO at up to 10 metres; pumps from 0.37 to 2.2 kW are factory-fitted with the FM300 functional module, which brings three analogue inputs, two Pt100\/1000 inputs, two LiqTec sensor inputs and two signal relays for anyone wiring the pump into a wider control scheme.\u003c\/p\u003e\n\u003cp\u003eOn efficiency, Grundfos rates the MGE motor at IE5 level from 0.37 to 26 kW, and states that the product complies with the ecodesign requirements for water pumps in the ErP Directive, Commission Regulation (EC) No 547\/2012. The hydraulic side is measured by the Minimum Efficiency Index, and the benchmark Grundfos quotes for the most efficient water pumps is MEI ≥ 0.70.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003csection\u003e\n\u003ch2 class=\"text-[24px] font-semibold tracking-tight\"\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"mt-4 overflow-hidden rounded-lg border border-slate-200\"\u003e\n\u003ctable class=\"w-full border-collapse text-left\"\u003e\n\u003ctbody class=\"divide-y divide-slate-200\"\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003ePump type\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003eVertical multistage centrifugal pump with integrated frequency converter\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003enon-self-priming, in-line ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003eMaximum flow\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003e240 m³\/h\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003eCRE 155 maximum, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003eMaximum head\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003e262 m\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003erange maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003eMaximum operating pressure\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003e30 bar\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003eCRE 32-6-2 to 32-10-2 and CRE 45-5-2 to 45-7, PJE, clamp, union or DIN connection; 16 or 25 bar on smaller sizes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003eLiquid temperature\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003e−30 to +120 °C\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003e−20 to +120 °C on CRE 1 to CRE 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003ePump sizes\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003eCRE 1, 3, 5, 10, 15, 20, 32, 45, 64, 95, 125, 155\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003erated flow 1.2 to 185 m³\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003eMaterials\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003eCast iron pump head and base; all other wetted parts EN 10088 1.4301 (AISI 304) stainless steel\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003eShaft seal\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003eMaintenance-free cartridge mechanical seal, HQQE\/V as standard\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003eMotor\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003eGrundfos MGE, totally enclosed fan-cooled, frequency converter built in\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003e0.37 to 1.5 kW single-phase; 0.37 to 26 kW three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003eMotor efficiency\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003eIE5 level, 0.37 to 26 kW\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003eEnclosure and insulation\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003eIP55 standard, IP66 optional; insulation class F\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003eSupply\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003e1 x 200-240 V (0.37-1.5 kW); 3 x 380-500 V (0.37-11 kW); 3 x 380-480 V (15-26 kW), 50\/60 Hz\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003ePipe connections\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003eOval flange or DN 25\/32 to DN 150, by size\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003ePJE (Victaulic) coupling available from DN 32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"bg-white\"\u003e\n\u003cth class=\"w-[30%] bg-slate-50\/60 px-5 py-3.5 align-top text-[13px] font-medium text-slate-500\"\u003eControl modes\u003c\/th\u003e\n\u003ctd class=\"px-5 py-3.5 align-top text-[14px] font-medium text-navy\"\u003eConstant pressure (factory setting) and constant curve\u003c\/td\u003e\n\u003ctd class=\"w-[22%] px-5 py-3.5 align-top text-[13px] leading-relaxed text-slate-500\"\u003eon pumps with the integrated pressure sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Grundfos","offers":[{"title":"Default Title","offer_id":52499198345518,"sku":"rundfos-rundfos-16","price":0.0,"currency_code":"AED","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1005\/7364\/3054\/files\/grundfos-cre-vertical-multistage-800x848.jpg?v=1787773138","url":"https:\/\/aharonipumps.com\/products\/grundfos-cre","provider":"Aharoni Pumps","version":"1.0","type":"link"}